Upgrading

Changes that need action on your side, per major version. Minor and patch releases are always safe to install without reading anything in advance — see the GitHub releases page for the full per-release changelog.

v5.x → v6.0

Two changes to be aware of before upgrading. Neither requires re-adding the integration or re-authorizing.

Automations comparing to the numeric state of running_state_raw or device_type_code will break

Affects: cloud entries with per-device sensors enabled, and every local Modbus entry.

Since #325, those two sensors are classified as enum and expose the decoded label ("Running", "Standby", "Emergency Stop", "SG3.6RS", "SH10RT", …) instead of the raw integer code they used to hold. This makes them useful on dashboards and in the Logbook, but it means an automation like this no longer matches:

# BEFORE (v5.x) — stops working after upgrade
- trigger: state
  entity_id: sensor.my_inverter_running_state_raw
  to: "4"

Change the comparison to the enum label:

# AFTER (v6.x)
- trigger: state
  entity_id: sensor.my_inverter_running_state_raw
  to: "Emergency Stop"

The label set is the values shown on the Sensors page for each enum sensor. Any automation that used the raw integer is worth checking after upgrade — HA won't warn you: it just silently stops firing.

Finding stale references

Search your automations and dashboards for running_state_raw, device_type_code (and the older inverter_state alias if you used it). Anything comparing to a numeric-looking string on those entities needs the enum label instead.

SBH cloud plants — battery State of Charge is now a proper percentage

Affects: cloud entries for SBH (residential battery / hybrid) plants where SOC previously reported values in the 0.00 – 1.00 range instead of 0 – 100.

Since #228, the integration scales those SOC readings to a proper 0-100 percentage server-side. If you added a manual * 100 in a template sensor, automation or Lovelace card to work around the old value, remove it — otherwise your value now reads e.g. 4200 when the battery is at 42%.

# BEFORE (v5.x) — remove after upgrade
template:
  - sensor:
      - name: "Battery SOC (percent)"
        state: "{{ states('sensor.plant_battery_soc') | float * 100 }}"

# AFTER (v6.x) — read the sensor directly
# sensor.plant_battery_soc already reports 0-100

Long-term statistics for these entities are not rewritten on upgrade — the old 0-1 values stay in the historical series. If your Energy dashboard graph has a step change at the upgrade time, that's why. Use the sungrow.backfill service to re-import the affected period if you want a clean history.

Also worth knowing

Not breaking (no user action required), but shape-changing enough to mention:

  • cloud_modbus transport retired. Entries that used the pre-v5 hybrid transport are auto-migrated on load — the modbus_host value is stripped from the cloud entry, and if the inverter serial is known, a separate local Modbus entry is created automatically alongside it. No user action needed, but the shape of what used to be one entry is now two. See Upgrading from hybrid.
  • Charge/Discharge Command select replaced by Battery Mode. The old select.*_charge_discharge_command entity has been superseded by select.*_battery_mode with a richer option set (Self-consumption / Force charge / Force discharge / Stop). Restored Charge / Discharge / Stop states from the old entity map onto the new options, so existing automations keep working; new automations should use the new entity or the sungrow.set_battery_mode service.